Fuses, Breakers, Fuse Holders, Sub Panels
Protect your investment with AM Solar’s assortment of RV specific fuses, circuit breakers, fuse holders, sub panels, fuse boxes, and disconnects. With over two decades of hands-on installation experience, AM Solar knows what works and how to use it. If you aren’t sure which components go with your specific application, the team at AM Solar can guide you and point you in the right direction.
Protect your investment with AM Solar’s assortment of RV specific fuses, circuit breakers, fuse holders, sub panels, fuse boxes, and disconnects. With over two decades of hands-on installation experience, AM Solar knows what works and how to use it. If you aren’t sure which components go with your specific application, the team at AM Solar can guide you and point you in the right direction.
Fuse Holders
Fuse holders house the fuses between the battery bank and DC loads or charging sources.
-
Class T Fuse & Holder
Class T Fuses are used as circuit protection between battery banks and inverters or alternators. AM Solar Part Number: 95F-CLST-110A, 95F-CLST-200A, 95F-CLST-300A, 95F-CLST-400A
-
ANL Fuse & Holder
ANL Fuses are used as circuit protection between battery banks and inverters or alternators. AM Solar Part Number: 95F-ANL-300A, 95F-ANL-400A
-
ATC Fuse Holder & Cap
ATC Fuses are commonly used in automotive applications between the battery bank and DC loads like lights and fans. AM Solar Part Number: FUSEHLDR-ATC
-
Mini Fuse Holder & Cap
Mini fuses are used for circuit protection between battery banks and some system control or monitoring components. AM Solar Part Number: FUSEHLDR-MINI
-
Maxi Fuse Holder & Cover
Maxi Fuses provide circuit protection typically between a charge controller or small inverter and a battery bank AM Solar Part Number: FUSEHLDR-MAXI
Fuses
Fuses provide circuit protection between the battery bank and a load or charging source. Class T fuses provide circuit protection between the battery bank and the inverter. They are also sometimes used between an alternator and a battery bank.
Inverter Rating / Fuse: >1500W – 110A, 1500W – 200A, 2000W – 300A, 3000W – 400AA spare fuse is recommended with with the purchase of a fuse & holder.
Maxi fuses are typically used for charge controllers or smaller inverters. ATC fuses are used for DC loads. Mini fuses are typically used for small system components like Battery Management Systems or monitors.
-
Spare Class T Fuses
Class T Fuses are used as circuit protection between a battery bank and an inverter. AM Solar Part Number: FUSE-CLST-110A, FUSE-CLST-200A, FUSE-CLST-300A, FUSE-CLST-400A
-
ATC Fuses (DELETE)
ATC Fuses are commonly used in automotive applications between the battery bank and DC loads like lights and fans.
- Dimensions: H 1.9” x W 4.2” x D 1.9”
Fuse Blocks
Fuse Blocks house the DC fuses between DC loads and the battery bank.
-
ST Fuse Block 6 Circuit
Compact ATO/ATC fuse block consolidates branch circuits and eliminates the tangle of in-line fuses for electronics and other appliances. AM Solar Part Number: FUSEHLDR-MULT
- Dimensions: H 4.9" x W 3.4" x D 1.5"
-
ST Fuse Block 12 Circuit
Compact ATO/ATC fuse block consolidates branch circuits and eliminates the tangle of in-line fuses for electronics and other appliances. AM Solar Part Number: FUSEHLDR-MULT12
Fuse Kits
-
ATC Fuse Kit
Add a fuse kit to a load or charging source. What you get: 1x FUSEHLDR-ATC ATC Fuse Holder & Cap 2x FUSE-ATC-015A/020A/025A/030A ATC Fuse-15/20/25/30 Amp 1x SPLICE-10-BUTT-HS 10-12 ga. Butt HS 1x LUG-10GA-RING-HS LUG-10GA-RING-H.S. AM Solar Part Number: 93F-ATC-015A, 93F-ATC-020A, 93F-ATC-025A, 93F-ATC-030A
Sub Panels (Breaker Boxes)
The breaker boxes house the breakers in the Main and Sub panels of an inverter/charger system. The 50A sub panel is recommended for 3000W or larger inverters.
-
Midnite Solar Baby DIN Mount Box
AC Distribution panel for 30A shore power systems AM Solar Part Number: BOX-MSB
-
Eaton Sub Panel Surface Mount
Breaker box for AC distribution, Rated for 40A. This box accommodates 3 x 1" wide single pole or double pole (tandem) breakers. Our most popular selection is 30/15, 15/20, 15/15. This provides for a 30A input from the inverter and 3 x 15A...
-
Eaton Sub Panel Flush Mount
Breaker box for AC distribution, Rated for 40A. This box accommodates 3 x 1" wide single pole or double pole (tandem) breakers. Our most popular selection is 30/15, 15/20, 15/15. This provides for a 30A input from the inverter and 3 x 15A...
-
Progressive Dynamics 5500 Series AC Distribution Panel
AC Load Center w/ 2 x 50A legs AM Solar Part Number: BOX-PD5500
AC Breakers
AC Breakers are located in the Main panel and Sub panel of an inverter/charger system
-
AC Breakers for Eaton box
Siemens breaker for AC distribution sub panel AM Solar Part Number: BRKR-AC-BRKR-015A, BRKR-AC-BRKR-020A, BRKR-AC-BRKR-030A, BRKR-AC-BRKR-050A
-
Slim AC Breakers for GE box
GE slim breaker for AC distribution sub panel AM Solar Part Number: BRKR-AC-SLIM-015A, BRKR-AC-SLIM-020A, BRKR-AC-SLIM-030A, BRKR-AC-SLIM-050A
-
Duplex AC Breakers for Eaton box
Siemens breaker for AC distribution sub panel AM Solar Part Number: BRKR-AC-BRKR-15/15, BRKR-AC-BRKR-20/20, BRKR-AC-BRKR-30/15
DC Breakers
DC Breakers are typically used between a charge controller and a battery bank, but can also be used between a battery bank and an inverter or alternator. When designing a solar charging system, select a breaker rated just above the current rating of the charge controller.
-
DC Breakers
Because of Direct Current's tendency to arc when disconnected, special breakers are needed. These DC breakers are ideally used between charge controllers and battery banks and on alternator or small inverter lines. AM Solar Part Number: BRKR-DC-BRKR-030A BRKR-DC-BRKR-040A BRKR-DC-BRKR-050A BRKR-DC-BRKR-060A BRKR-DC-BRKR-080A BRKR-DC-BRKR-100A BRKR-DC-BRKR-120A...
- Dimensions: H 1.8" x W 2.3" x D 3.5"
-
Din Mount DC Breakers
DIN-mount breakers fit MidNite Solar enclosures & array combiners. These breakers are polarized, so the positive wire from the power source needs to be connected to the "+" side of the breaker. The maximum PV array voltage must not exceed the voltage rating...
-
High Current On/Off Mini Switch
*Color may vary based on availability. This will have no effect on performance.* Manually disconnect high current lines. This switch is typically used between a combiner box and a charge controller, or between a battery bank and an inverter. AM Solar Part Number:...
-
Blue Sea 9003E E-Series Master Battery Switch Single Circuit ON/OFF
Manually disconnect high current lines. This switch is typically used between a battery bank and an inverter. We recommend this with the 3000VA Victron Inverter systems. This switch is slightly larger and with a higher current rating than the High Current On/Off Mini...
Temperature Sensor for BMV-712
Support from AMSolar is definitely 5 stars. 1st line of support for Victron equipment provided through distributors. AMSolar likely one of the best when it comes to RVs.
Tom B