Product Description
Victron Cyrix battery combiners connect your house battery bank to your starter battery and alternator to allow alternator charging. Additionally, when a charge is applied to a house battery bank the Cyrix will close and allow current to flow to the starter battery. Select an appropriate Cyrix based on your house battery type and alternator current rating.
AM Solar Part Number: RELAY-VTC120, RELAY-VTCY
-
Wiring Diagrams
These diagrams demonstrate how to integrate a Cyrix into an existing system. None of the cable, lugs, or circuit protection components are included. Full kits can be found below.
These devices are compatible with both AGM and Lithium battery systems.
LED indicator meaning:
OFF – No batteries detected (check your chassis ground)
Rapid Flash – Only one battery detected
Slow Flash – Batteries detected, but not connected
Solid (or fluttering) – Batteries connectedWhen a Cyrix would close:
13,4 V < V < 13,7 V: 120 s
13,7 V < V < 13,9 V: 30 s V > 13,9 V: 4 sWhen a Cyrix would open:
13,3 V < V < 13,2 V: 10 s
V < 13,2 V: immediate
What our customers are saying
There are no reviews for this product yet. You can be first.