Back

Installation Summary

  • 990Ah 12VDC Victron Energy Smart LiFePO4 Lithium Battery Bank w/ Lynx Smart BMS 500 Battery Management System

  • 60A DC/DC Alternator Charging System

  • 345W Solar Array configured in parallel to a Victron Energy 50A MPPT Charging Core

  • Starlink antenna system
  • 12VDC/3000VA Victron Energy 1x120V AC Input/Output System w/ Micro Air Easy Start, Watchdog, & Cerbo GX/Touch 70 Monitor

Want a quote for a similar project? Complete this form.

 

Date of Completion: February 22, 2024

System Details

Solar Wattage: 300W

Charge Controller: Complete 50A Victron SmartSolar Charge Controller Kit

Inverter System:Victron Multiplus II 1x120V 3000VA Inverter Kit- Full Pass

Battery Type: LiFePO4 Victron 12.8V 330ah

# of Batteries: 3

Battery Ah Rating: 3x 330Ah

Battery Model: Lithium Smart Battery 12.8V | 330A

Alternator Charging System:  Victron Orion 12|12 30A DC/DC Charger

 

Battery Bank w/Victron Energy BMV-712 Battery Monitoring System

Installation of 3x 330ah Victron Smart LiFePO4 lithium batteries.

 

 

Victron Lithium Lynx Smart BMS 500 kit.

 

Lynx Smart BMS 500 w/ Lynx Distributor system in storage space below the sofa bed, using a Master on/off Switch & 400A ANL fuse assembly as the main system fuse at the most (+) battery terminal.

 

60A DC/DC Alternator Charging System

Re-wire the factory battery combiner to serve as the dual non-isolated 30A Orion input source control relay.

 

300W Solar Array

Remove dual 100W flexible panels, install 3x 100W Zamp Obsidian panels w/low-profile mounting.wired to a Zamp 4-port roof box & Victron 50A MPPT system core, & install a portable panel side port to the central controller kit.

 

Wire configuration within solar combiner box.

 

Fully assembled Zamp roof combiner box connected to Zamp Obsidian 100W panels.

 

Victron 50A MPPT system core wired to a Zamp 4-port roof combiner box.

 

Victron 3000VA Inverter / 120ADC Charger System

Remove factory 1kW Magnum inverter/charger, install a 12/3kVA MP-ll 1x120V in full passthrough configuration with Cerbo GX/Touch 70 monitoring system. Protect MP-ll with 400A Mega Fuse (w/ spare) in Lynx Distributor.

 

 

Hardwired a 30A Watchdog EPO AC input protection.

 

Touch 70 mounted in the control cabinet.

Want a quote for a similar project? Complete this form.